Water Treatment Chemicals

Reverse Osmosis Chemicals, Industrial & Commercial RO Chemicals

 


Reverse osmosis chemicals
to improve the performance of your reverse osmosis system’s membranes.

Reverse osmosis (RO) membrane performance can be negatively impacted by impurities that build up on the membrane surface during operations. Suspended solids, microorganisms and mineral scale can foul membrane elements. These deposits can cause loss in output and/or rejection levels and reduce total system performance.

The membrane separation process utilizes a high-pressure feed to force water through a semi-permeable barrier. As the water passes through the membrane, contaminates are rejected and eventually flushed to the waste stream. The concentration of the contaminants is crucial to determine the design and operation of the membrane system. During normal operations, membranes can become fouled by colloidal material, inorganic oxides, biological matter, and scaling salts.

Fouling involves the entrapment of material in the feed water or deposits on the membrane surface. These deposits can accrue until they cause a reduction in flow, increase in feed pressure requirements, loss of salt rejection, or all three.

SAI TREAT membrane chemical's products are formulated to treat a wide variety of commercial reverse osmosis (RO) systems, nanofiltration (NF), and ultrafiltration (UF) systems.

SAI TREAT offers a wide array of products to help you improve the performance of your membranes:

Antiscalants:

The Antiscalant chemical from SAI TREAT is designed to eliminate scale and reduce fouling inmembrane systems, regardless of the feedwater source.

Successful membrane cleaning relies on both the effectiveness of the cleaning compounds and the design and operation of the cleaning equipment. SAI TREAT can offer suggestions on cleaning system design and cleaning procedures to ensure the most effective results.

Antifoulants:

Effective control of bacterial growth and slime. 

Need better membrane performance? 

At SAI TREAT , we understand how critical membrane performance is to your reverse osmosis system. We offer a complete line of products to extend the life of membrane elements, improve the quality of water produced and reduce the amount of maintenance and cleaning your reverse osmosis system requires.

Product Model No. :

SAI-TREAT R.W.T. 1               R.O. ANTISCALANT
SAI-TREAT R.W.T. 2               R.O. CLEANER
SAI-TREAT R.W.T. 3               R.O. CLEANER
SAI-TREAT R.O. 7                   R.O. ANTISCALANT

 

Boiler Water treatment Chemical

The treatment of water for steam generation is one of the most significant branches of water chemistry. Industries use steam, either in the process or generating power. Generation of steam is energy intensive and costly, therefore efficient production and utilization of steam is a prerequisite to keep over all cost of production down. Strategy for the boiler water treatment should be to use the boiler that operates with the highest efficiency for the longest possible time
Boiler water should be treated properly to prevent pitting/corrosion, scaling and carryover even hot blast of tubes. Using some of the specific result oriented additives can prevent these problems to facilitate fast, safe & reliable steam generation.

Product Model No. :

SAI-TREAT B.W.T 1         ANTISCALANT

SAI-TREAT B.W.T 2         OXYGEN SCAVENGER

SAI-TREAT B.W.T 3         pH BOOSTER
SAI-TREAT MP                 MULTI PURPOSE

 

COOLING WATER TREATMENT

 
The Primary objective of cooling water treatment is to facilitate easy heat rejection and minimize water consumption. Cooling involves the transfer of heat (Btu’s Kcal/Kg) from one substance to another. The substance that loses heat is said to be cooled, and the one that receives the heat is referred to as the coolant.
Cooling water for the industries if untreated cause several problem i.e. corrosion, scaling, fouling & microbiological growth in cooling towers, condensers, coolers and other parts, resulting in production loss, equipments failure and breakdowns.

SAI-TREAT C.W.T 1           ANTISCALANT and ANTICORROSION
SAI-TREAT C.W.T. 2          ANTISCALANT and ANTICORROSION
SAI-TREAT C.W.T. 3          BIOCIDE
SAI-TREAT 205                  BIOCIDE

 

DESCALING/CLEANING CHEMICALS

 

 

Descaling/Chemical cleaning is more effective as the removal of inorganic and organic foulants from process lines, equipments, surface etc. Cleaning should be combination of three elements i.e. Solvents (acid, alkali, surfactant), Fluid velocity (stirring, spraying, agitation, air rumbling and steam addition etc) Heat (hot water or hot surface). Cleaning is divided into two categories : pre operational cleaning and routine maintenance cleaning.

SAI TREAT B.W.T 4

 

 

FUEL ADDITIVE / FIRESIDE CHEMICALS

 


Sai Treat fuel additives/fireside is designed keeping in mind typical fuel oil related problems and overall improvement in fuel economy. Use of SAI-TREAT fuel additives insures reduction in oil sludge, prevention of corrosion in oil storage tank, pipelines and an objective of cleaner environment.
Sai Treat fuel additives also help to improve overall combustion improvement by reduction in soot and clinker formation as well as stack temperature. Fireside chemicals contain silicate based combustion catalyst, slag modifiers, corrosion inhibitors and dust suppressants that help overall combustion resulting in better system performance.

SAI-TREAT F.W.T 1 FUEL ADDITIVES
SAI-TREAT F.W.T 2 SOOT RELEASE

 

SWIMMING POOL CHEMICAL


The Primary objective of this chemical is to maintain swimming pool water clean so that water can be used for more cycle for concentration. It is very effective product for wide range of water quality.

SAI-TREAT S.W.T 1 CHLORINATION
SAI-TREAT S.W.T 2 CHLORINATION


WASTE WATER TREATMENT



Synthetic polymeric flocculants/ polyelectrolytes are large water molecules made up of small building blocks called monomers. These materials react with the colloidal material in the effluent water to formation of floc. Wastewater additives are polyelectrolytes, defoamer & cultured bacteria to maintain desired wastewater parameters.
Effuent/Sewage treatment program consist of complete removal of pollutants and properly maintaining BOD, COD, MLSS and other desired parameters in wastewater. Less or compact sludge should be produced to minimize sludge handling & disposal cost. Flocculants don’t add solids and also don’t affect the pH of the water unlike coagulants and alkali.

SAI-TREAT  E.T.P. 1
SAI-TREAT  E.T.P. 2
SAI-TREAT  E.T.P. 3
SAI-TREAT 
FLOCULANT

 

             
© 1989-2016 Anandi Specialities & Services Pvt. Ltd. , All Rights Reserved. Careers  
Anandi Specialities & Services Pvt. Ltd. 
175, 1st Floor, V-Mall, Next to Sai Baba Temple ,
W E Highway , Kandivali (East).
Mumbai- 400101.(INDIA) 
Email : sales@saitreat.com
www.saitreat.com
Tel : 022 42974397 Fax : 022 28542480